Our staff through skilled training. Skilled skilled knowledge, potent sense of company, to satisfy the provider requirements of consumers for Foam Pipe Insulation Glue , Air Conditioner Insulation Hose , Electric Insulationmanufacturers , We welcome you to definitely join us in this path of making a affluent and productive business together.
Big Discount Cryogenic Insulation Thickness Calculation - elastomeric NBR/PVC rubber foam thermal insulation pipe tubing – Kingflex Detail:

Black, red, green and yellow color are all available.

rubber foam insulation tube

The expanded closed-cell structure of Kingflex Rubber Foam Insulation Tube makes it an efficient insulation. It is manufactured without the use of CFC’s, HFC’s or HCFC’s. It is also formaldehyde free, low VOCs, fiber free, dust free and resists mold and mildew. Kingflex Rubber Foam Insulation Tube can be made with special antimicrobial product protection for added defense against mold on the insulation.

 Technical Data

Property

Unit

Value

Test Method

Temperature range

°C

(-50 – 110)

GB/T 17794-1999

Density range

Kg/m3

45-65Kg/m3

ASTM D1667

Water vapor permeability

Kg/(m.s.pa)

 ≤0.91×10 ﹣¹³

DIN 52 615                           BS 4370 Part 2 1973

μ

-

≥10000

Thermal Conductivity

W/(m.k)

≤0.030 (-20°C)

ASTM C 518

≤0.032 (0°C)

≤0.036 (40°C)

Fire Rating

-

Class 0 & Class 1

BS 476 Part 6 part 7

 Flame Spread and Smoke Developed Index

25/50

ASTM E 84

Oxygen Index

≥36

GB/T 2406,ISO4589

Water Absorption,%by Volume

%

20%

ASTM C 209

Dimension Stability

≤5

 ASTM C534

Fungi resistance

-

Good

ASTM 21

Ozone resistance

Good

GB/T 7762-1987

Resistance to U.V. and weather

Good

ASTM G23

Standard Dimensions

NO.

Copper Tube

Steel Pipe

Internal      Φ            mm

9mm ·3/8″FF

13mm ·1/2″HH

19mm ·3/4″MM

25mm ·1″RR

Nom.   ID Inches

Nom.   ID Inches

I.PS. Inches

Φ   External    mm

Φ    Nominal   mm

Ref. Wall*ID

Lengths (2m)     per cart

Ref. Wall*ID

Lengths (2m)     per cart

Ref. Wall*ID

Lengths (2m)     per cart

Ref. Wall*ID

Lengths (2m)     per cart

1

 1/4

6.4

7.1  8.5

9*06

170

13*6

90

19*6

50

25*6

35

2

 3/8

9.5

 1/8

10.2

6

11.1  12.5

9*09

135

13*10

80

19*10

40

25*10

25

3

 1/2

12.7

12.5

13.1  14.5

 9*13

115

13*13

65

19*13

40

25*13

25

4

 5/8

15.9

 1/4

13.5

8

16.1  17.5

9*16

90

13*16

60

19*16

35

25*16

20

5

 3/4

19.1

19.0  20.5

9*19

76

13*19

45

19*19

30

25*20

20

6

 7/8

22.0

 1/2

21.3

15

23.0  24.5

9*22

70

13*22

40

19*22

30

25*22

20

7

1

25.4

25.0

26.0  27.5

9*25

55

13*25

40

19*25

25

25*25

20

8

1 1/8

28.6

 3/4

26.9

20

29.0  30.5

9*28

50

13*28

36

19*28

24

25*28

18

9

32.0

32.5  35.0

9*32

40

13*32

30

19*32

20

25*32

15

10

1 3/8

34.9

1

33.7

25

36.0  38.0

9*35

36

13*35

30

19*35

20

25*35

15

11

1 1/2

38.0

38.0

39.0  41.0

9*38

36

13*38

24

19*38

17

25*38

12

12

1 5/8

41.3

1 1/2

42.4

32

43.5  45.5

9*42

30

13*42

25

19*42

17

25*42

12

13

44.5

44.5

45.5  47.5

9*45

25

13*45

20

19*45

16

25*45

12

14

1 7/8

48.0

1 1/2

48.3

40

49.5  51.5

9*48

25

13*48

20

19*48

15

25*48

12

15

2 1/8

54.0

54.0

55.0  57.0

9*54

25

13*54

20

19*54

15

25*54

10

16

2

57.1

57.0

58.0  60.0

13*57

18

19*57

12

25*57

9

17

2 3/8

60.3

2

60.3

50

61.5  63.5

13*60

18

19*60

12

25*60

9

18

2 5/8

67.0

67.5  70.5

13*67

15

19*67

10

25*67

8

19

3

76.2

2 1/2

76.1

65

77.0  79.5

13*76

12

19*76

10

25*76

6

20

3 1/8

80.0

13*80

12

19*80

10

25*80

6

21

3 1/2

88.9

3

88.9

80

90.5  93.5

13*89

10

19*89

8

25*89

6

22

4 1/4

108.0

108.0

108  111

13*108

6

19*108

6

25*108

5

 Tolerance: Thickness

士 1.3mm

士 2.0mm

士 2.4mm

士 2.4mm

Production process

1

Application

2

Kingflex Rubber Foam Insulation Tube is used to retard heat gain and control condensation drip from chilled-water and refrigeration systems. It also efficiently reduces heat flow for hot-water plumbing and liquid-heating and dual-temperature piping. The recommended temperature usage range for Kingflex Rubber Foam Insulation Tube is -297°F to +220°F(-183°C to +105°C).

For use on cold pipes, Kingflex Rubber Foam Insulation Tube thicknesses have been calculated to control condensation on the insulation outer surface, as shown in the table of thickness recommendations.

Installation

1625813793(1)


Product detail pictures:

Big Discount Cryogenic Insulation Thickness Calculation - elastomeric NBR/PVC rubber foam thermal insulation pipe tubing – Kingflex detail pictures

Big Discount Cryogenic Insulation Thickness Calculation - elastomeric NBR/PVC rubber foam thermal insulation pipe tubing – Kingflex detail pictures

Big Discount Cryogenic Insulation Thickness Calculation - elastomeric NBR/PVC rubber foam thermal insulation pipe tubing – Kingflex detail pictures


Related Product Guide:

Our items are commonly identified and trusted by people and can fulfill repeatedly altering economic and social wants of Big Discount Cryogenic Insulation Thickness Calculation - elastomeric NBR/PVC rubber foam thermal insulation pipe tubing – Kingflex , The product will supply to all over the world, such as: Slovakia, Sacramento, Provence, Facing fierce global market competition, we have launched the brand building strategy and updated the spirit of "human-oriented and faithful service", with an aim to gain global recognition and sustainable development.
  • The supplier cooperation attitude is very good, encountered various problems, always willing to cooperate with us, to us as the real God.
    5 Stars By Ryan from Georgia - 2018.11.11 19:52
    Hope that the company could stick to the enterprise spirit of "Quality, Efficiency, Innovation and Integrity", it will be better and better in the future.
    5 Stars By Frank from Amsterdam - 2018.06.26 19:27