Factory Supply Air Duct Need Insulation - elastomeric NBR/PVC rubber foam thermal insulation pipe tubing – Kingflex


Product Detail

Product Tags

Related Video

Feedback (2)

With this motto in mind, we have become one of the most technologically innovative, cost-efficient, and price-competitive manufacturers for System Thermal Solution Compromised , Duct Lagging Acoustic , Foam Pipe Insulation Glue , As we're moving forward, we continue to keep an eye on our ever-expanding merchandise range and make improvement to our services.
Factory Supply Air Duct Need Insulation - elastomeric NBR/PVC rubber foam thermal insulation pipe tubing – Kingflex Detail:

Black, red, green and yellow color are all available.

rubber foam insulation tube

The expanded closed-cell structure of Kingflex Rubber Foam Insulation Tube makes it an efficient insulation. It is manufactured without the use of CFC’s, HFC’s or HCFC’s. It is also formaldehyde free, low VOCs, fiber free, dust free and resists mold and mildew. Kingflex Rubber Foam Insulation Tube can be made with special antimicrobial product protection for added defense against mold on the insulation.

 Technical Data

Property

Unit

Value

Test Method

Temperature range

°C

(-50 – 110)

GB/T 17794-1999

Density range

Kg/m3

45-65Kg/m3

ASTM D1667

Water vapor permeability

Kg/(m.s.pa)

 ≤0.91×10 ﹣¹³

DIN 52 615                           BS 4370 Part 2 1973

μ

-

≥10000

Thermal Conductivity

W/(m.k)

≤0.030 (-20°C)

ASTM C 518

≤0.032 (0°C)

≤0.036 (40°C)

Fire Rating

-

Class 0 & Class 1

BS 476 Part 6 part 7

 Flame Spread and Smoke Developed Index

25/50

ASTM E 84

Oxygen Index

≥36

GB/T 2406,ISO4589

Water Absorption,%by Volume

%

20%

ASTM C 209

Dimension Stability

≤5

 ASTM C534

Fungi resistance

-

Good

ASTM 21

Ozone resistance

Good

GB/T 7762-1987

Resistance to U.V. and weather

Good

ASTM G23

Standard Dimensions

NO.

Copper Tube

Steel Pipe

Internal      Φ            mm

9mm ·3/8″FF

13mm ·1/2″HH

19mm ·3/4″MM

25mm ·1″RR

Nom.   ID Inches

Nom.   ID Inches

I.PS. Inches

Φ   External    mm

Φ    Nominal   mm

Ref. Wall*ID

Lengths (2m)     per cart

Ref. Wall*ID

Lengths (2m)     per cart

Ref. Wall*ID

Lengths (2m)     per cart

Ref. Wall*ID

Lengths (2m)     per cart

1

 1/4

6.4

7.1  8.5

9*06

170

13*6

90

19*6

50

25*6

35

2

 3/8

9.5

 1/8

10.2

6

11.1  12.5

9*09

135

13*10

80

19*10

40

25*10

25

3

 1/2

12.7

12.5

13.1  14.5

 9*13

115

13*13

65

19*13

40

25*13

25

4

 5/8

15.9

 1/4

13.5

8

16.1  17.5

9*16

90

13*16

60

19*16

35

25*16

20

5

 3/4

19.1

19.0  20.5

9*19

76

13*19

45

19*19

30

25*20

20

6

 7/8

22.0

 1/2

21.3

15

23.0  24.5

9*22

70

13*22

40

19*22

30

25*22

20

7

1

25.4

25.0

26.0  27.5

9*25

55

13*25

40

19*25

25

25*25

20

8

1 1/8

28.6

 3/4

26.9

20

29.0  30.5

9*28

50

13*28

36

19*28

24

25*28

18

9

32.0

32.5  35.0

9*32

40

13*32

30

19*32

20

25*32

15

10

1 3/8

34.9

1

33.7

25

36.0  38.0

9*35

36

13*35

30

19*35

20

25*35

15

11

1 1/2

38.0

38.0

39.0  41.0

9*38

36

13*38

24

19*38

17

25*38

12

12

1 5/8

41.3

1 1/2

42.4

32

43.5  45.5

9*42

30

13*42

25

19*42

17

25*42

12

13

44.5

44.5

45.5  47.5

9*45

25

13*45

20

19*45

16

25*45

12

14

1 7/8

48.0

1 1/2

48.3

40

49.5  51.5

9*48

25

13*48

20

19*48

15

25*48

12

15

2 1/8

54.0

54.0

55.0  57.0

9*54

25

13*54

20

19*54

15

25*54

10

16

2

57.1

57.0

58.0  60.0

13*57

18

19*57

12

25*57

9

17

2 3/8

60.3

2

60.3

50

61.5  63.5

13*60

18

19*60

12

25*60

9

18

2 5/8

67.0

67.5  70.5

13*67

15

19*67

10

25*67

8

19

3

76.2

2 1/2

76.1

65

77.0  79.5

13*76

12

19*76

10

25*76

6

20

3 1/8

80.0

13*80

12

19*80

10

25*80

6

21

3 1/2

88.9

3

88.9

80

90.5  93.5

13*89

10

19*89

8

25*89

6

22

4 1/4

108.0

108.0

108  111

13*108

6

19*108

6

25*108

5

 Tolerance: Thickness

士 1.3mm

士 2.0mm

士 2.4mm

士 2.4mm

Production process

1

Application

2

Kingflex Rubber Foam Insulation Tube is used to retard heat gain and control condensation drip from chilled-water and refrigeration systems. It also efficiently reduces heat flow for hot-water plumbing and liquid-heating and dual-temperature piping. The recommended temperature usage range for Kingflex Rubber Foam Insulation Tube is -297°F to +220°F(-183°C to +105°C).

For use on cold pipes, Kingflex Rubber Foam Insulation Tube thicknesses have been calculated to control condensation on the insulation outer surface, as shown in the table of thickness recommendations.

Installation

1625813793(1)


Product detail pictures:

Factory Supply Air Duct Need Insulation - elastomeric NBR/PVC rubber foam thermal insulation pipe tubing – Kingflex detail pictures

Factory Supply Air Duct Need Insulation - elastomeric NBR/PVC rubber foam thermal insulation pipe tubing – Kingflex detail pictures

Factory Supply Air Duct Need Insulation - elastomeric NBR/PVC rubber foam thermal insulation pipe tubing – Kingflex detail pictures


Related Product Guide:

We know that we only thrive if we will guarantee our combined cost competiveness and high-quality advantageous at the same time for Factory Supply Air Duct Need Insulation - elastomeric NBR/PVC rubber foam thermal insulation pipe tubing – Kingflex , The product will supply to all over the world, such as: Casablanca, Germany, Finland, Our company is working by the operation principle of "integrity-based, cooperation created, people oriented, win-win cooperation". We hope we can have a friendly relationship with businessman from all over the world.
  • In general, we are satisfied with all aspects, cheap, high-quality, fast delivery and good procuct style, we will have follow-up cooperation!
    5 Stars By Hazel from Pretoria - 2018.12.28 15:18
    The factory can meet continuously developing economic and market needs, so that their products are widely recognized and trusted, and that's why we chose this company.
    5 Stars By Martin Tesch from venezuela - 2017.08.18 18:38